The Fluke 374 True-rms ClampMeter can read up to 600 V and 600 A in both ac and dc modes. Additionally, the374 is compatible with the new iFlex flexible current probe (sold separately),which increases the measurement range to 2500 A ac and provides increaseddisplay flexibility, and improved wire access.

Safety Conformance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV


Features and benefits

  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy
  • The removable magnetic display can be conveniently mounted where it is easily seen
  • iFlex flexible current probe expands the measurement range to 2500 A ac
  • CAT IV 600 V, CAT III 1000 V
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

Safety conformance
IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV

What?s the difference between the clampmeter models?

ÿ Fluke-365 Fluke-373 Fluke-374 Fluke-375 Fluke-376 Fluke-381
Measure ac current 200.0 A 600.0 A 600.0 A 600.0 A 999.9 A 999.9 A
Measure ac currentvia iFlex ÿ ÿ 2500 A 2500 A 2500 A 2500 A
Measure ac voltage 600.0 V 600.0 V 600.0 V 600.0 V 600.0 V 600.0 V
Measure continuity ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω
Measure dc voltage 200.0 A ÿ 600.0 A 600.0 A 999.9 A 999.9 A
Measure dc voltage 600.0 V 600.0 V 600.0 V 600.0 V 600.0 V 600.0 V
Measure resistance 6,000 Ω 6,000 Ω 6,000 Ω 60k Ω 60k Ω 60k Ω
Measure frequency ÿ ÿ ÿ 500 Hz 500 Hz 500 Hz
Measure inrush ÿ ÿ 100 mS 100 mS 100 mS 100 mS
Work in poorly litareas Backlight Backlight Backlight Backlight Backlight Backlight
Measure non-linearloads True-rms True-rms True-rms True-rms True-rms True-rms

ÿ

Specifications
Diameter of measurableconductor 01.26? or 32 mm max
Operating temperature -14 to 122§F (-10 to 50§C)
Storage Temperature -40 to 140§F (-40 to 60§C)
Operating Humidity <90% @ 10 to 30 §C, <75% @ 30 to 40§C
Operating Altitude 0 to 3000 m
Size 232 x 85 x 45 mm, (9.133 x 3.346 x 1.771in.)
Weight 370g, (13 oz.)
Temperature Coefficient 0.01% §C
( 28§C)
Warranty Three years for electronics
One year for cable and clamp assembly