Home » Shop » hot sale » Absolute Process Instruments APD 4300 D _ DC to DC transmitter. Fully isolated.

Absolute Process Instruments APD 4300 D _ DC to DC transmitter. Fully isolated.

Original price was: $303.20.Current price is: $222.97.

Sale!

81 in stock

SKU: APD 4300 D Category:

Absolute Process Instruments APD 4300 D _ DC to DC transmitter. Fully isolated.

Cecomp Electronics, APD 4300 D, DC to DC Isolated Signal Conditioner, 9-30 VDC, 10-32 VAC Power

Features:

  • Removable Plugs for Faster Installation
  • Full 1200 V Input/Output/Power Isolation
  • Zero and Span Output Calibration Potentiometers
  • Input and Output LoopTracker® LEDs
  • Functional Test Button with Remote Capability
  • Built-In Loop Power Supplies for Input and Output

Applications:

  • Convert, Boost, Rescale Process Signals
  • Isolate Single-Ended (Common Ground) PLC Inputs
  • Interface Process Signals with Panel Meters, PLCs, Recorders, Data Acquisition, DCS, and SCADA Systems

The APD 4300 D accepts a DC voltage or current input and provides an optically isolated DC voltage or current output that is linearly related to the input.

Typical applications include signal isolation, conversion, boosting or a combination of the three. Full 3-way isolation (input, output, power) makes this module useful for ground loop elimination, common mode signal rejection or noise pickup reduction.

The APD 4300 D can be factory configured for 4-20 mA input and 4-20 mA output to solve signal isolation, ground loop, common mode, or noise pickup problems for non-isolated PLC inputs.

For maximum versatility loop excitation power supplies are included for the input and output. A mA input and a mA output can be selectively wired for sinking or sourcing. This allows the APD 4300 D to work with any combination of sinking or sourcing mA transmitters and sinking or sourcing mA receiving devices.

LoopTracker

API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting.

Functional Test

An API exclusive feature includes the Functional Test Button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of output span.

The functional test button greatly aids in saving time during initial startup and/or troubleshooting. The functional test can also be enabled with a customersupplied external contact closure across terminals 5 and 6. This allows remote testing of the output or, for example, a PLC-controlled manual override setting.

Specifications Table:

Input 0-100 mV to 0-300 VDC, Bipolar Voltages, 0-1 mA to 0-1000 mADC
Output 0-1 V to ±10 VDC or 0-1 mA to 4-20 mA
DC Input Range

Factory configured, please specify input range or consult factory for special ranges.

See table on other side for common ranges.

Voltage: 0-100 mVDC to 0-300 VDC

Bipolar voltage: ±100 mVDC to ±10 VDC

Current: 0-1 mADC to 0-1000 mADC

Input Impedance (Voltage) 200 kΩ minimum
Input Voltage Burden (Current) 1.25 VDC maximum
Common Mode Rejection 120 dB minimum
Input Loop Power Supply

15 VDC nominal, regulated, 25 mADC

Max. ripple, less than 10 mVRMS

May be selectively wired for sinking or sourcing mA input

DC Output Ranges

Factory configured, specify output range

Voltage, 10 mA max.: 0-1 VDC to 0-10 VDC

Voltage, M09 option: 0-10 VDC to 0-20 VDC

Bipolar voltage: ±1 VDC to ±10 VDC

Current: 0-1 mADC to 0-20 mADC, 20 V compliance, 1000 Ω at 20 mA

Output Calibration

Multi-turn zero and span potentiometers

±15% of span adjustment range typical

Output Loop Power Supply 20 VDC nom., regulated, 25 mADC, <10 mVRMS max. ripple. May be selectively wired for sinking or sourcing mA output
Output Test/Override Potentiometer adjustable 0-100% of span
Output Ripple and Noise Less than 10 mVRMS ripple and noise
Linearity Better than ±0.1% of span
Ambient Temperature Range and Stability

-10°C to +60°C operating ambient

Better than ±0.02% of span per °C stability

Response Time 70 milliseconds nominal
Isolation

1200 VRMS minimum

Full isolation: power to input, power to output, input to output

Connectors Four 4-terminal removable connectors, 14 AWG max wire size
Power 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum