Home » Shop » Accessories » AC/DC Scope Probe

AC/DC Scope Probe

Original price was: $1,380.00.Current price is: $795.06.

Sale!

45 in stock

SKU: I50S Category:
  • Bandwidth DC up to 50 MHz
  • Nominal current 30 A
  • Max. current 50 A, <10 s
  • Automatic zero adjustment and degauss functions
  • Overheating and Head Unlocked warning
  • Rise time <7 ns
  • External magnetic field rejection rate AC and DC 60 dB
  • Rejection rate of fast dv/dt (5kV/_s) <15 mA t
ElectricalCharacteristics
Nominalcurrent (In)
 ± 30 A dc or A rms
Measuringrange (duration <10 sec)
 I max ±50 A pk
OutputSensitivity
 low range 1 V/A (1 MΩ)
 High range 100 mV/A (1 MΩ)
Overallaccuracy (dc to 100 Hz at 25 °C)
 ± 0.5 % at In typical
 ± 1.5 % at I max
Gainvariation (max)
 ± 0.04 % of rdg/ °C
Stepresponse
 in Data Sheet
Frequencyresponse
 in Data Sheet
Insertionimpedance (ZI)
 in Data Sheet
 <0.1 Ω up to 10 MHz
 <0.4 Ω 10 MHz to 50 MHz
Externalmagnetic field rejection rate
 60 dB (ac and dc)
Rejectionrate of fast dV/dt at 5 kV/ μs
 <15 m At (during dV/dt)
Outputnoise level (measured with a filter at 25 MHz)
 1 m At rms typical
Outputnoise level (measured with a filter at 25 MHz)
 9 mA tpp
DynamicCharacteristics
Bandwidth
 DC to 50MHz(-3dB)
Frequencyderating (see Figure 4)
 10 A at 10MHz
Rise time,(10 % to 90 %)
 tr <7ns
Delay time
 td <25 ns
Overshoot
 <5 % of reading
GeneralCharacteristics
Aperturedimensions
 5 x 5 mm (0.2 in x 0.2 in)
Maxprimary conductor temp
 60 ° C (140 °F)
Dielectricwithstand
 1350 Vrms / 50 Hz / 1 min
WorkingVoltage
 300 Vrms or DC (CAT I)
 150 Vrms or DC (CAT II)
Operatingtemperature
 °C to + 40 °C (32 °F to 104 °F)
Storagetemperature
 -10 °C to + 60 °C (14 °F to 140 °F)
MaximumAltitude
 2000 m (6600 ft)
Maximumrelative humidity
 80 % , 31 °C (87 °F)
Environment
 indoor use only
Powersupply
 ± 12 V ± 0.5 V
Currentconsumption at nominal
 30 A 550 mA
Currentconsumption during demagnetization
 1.3 A (for 6 sec) Probe
Outputcable length
 2 m (6.6 ft)