GeneralSpecifications
Probe andCable Material
 TPE rubber, reinforced insulation
 UL94 V-0, Colour: RED Munsell 7.5
 R 1/14
CouplingsMaterial
 Polypropylene, UL94 V-0
ProbeCable Length
 610 mm
ProbeCable Diameter
 12.4 mm
ProbeCable Bend Radius
 40 mm
Outputcable length
 2.5 meters RG58
OutputConnector
 Safety BNC Connector
OperatingRange
 -20 to +90°C
StorageTemperature
 -40 to +105°C
OperatingHumidity
 15% to 85% (non condensing)
Degree ofprotection (Probe)
 IP41
Specifications
CurrentRange
 3000 A AC RMS
Voltageoutput (@1000 ARMS, 50 Hz)
 85 mV
Accuracy
 ± 1% of reading
 (@ 25°C, 50 Hz)
Linearity(10% to 100% of range)
 ± 0.2% of reading
Noise (10Hz – 7 kHz)
 1.0 mV ACRMS
Outputimpedance
 82 Ω min
LoadImpedance
 50 kΩ
InternalResistance per 100 mm probe length
 10.5Ω ± 5%
Bandwidth(-3dB)
 10 Hz to 7 kHz
PhaseError (45 – 65 Hz)
 ±1°
PositionSensitivity
 ± 2% of reading max.
TemperatureCoefficient
 ± 0.08% max of reading per °C
WorkingVoltage (see Safety Standards section)
 1000 V AC RMS or DC (head)
 30 V max. (output)
SafetySpecifications
SafetyStandards
 BS EN 61010-1 2001
 BS EN 61010-2-032 2002
 BS EN 61010-031 2002, 1000 VRMS, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 1000 V ACRMS or DC and frequencies below 1 kHz.
 Please note that this probe is designed to work with Fluke 435, if used with other products
 safety rating for the output to earth is limited to 600V ACRMS or DC