SKU: I310S Category:
  • Current Ranges: 30 A and 300 A ACRMS or ñ45 A and 450 A DC
  • Measuring Ranges: ñ45 A and ñ 450 A
  • Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
  • Resolution: ñ50 mA (40 A) to ñ100 mA (400 A)
  • Load Impedance:> 10 k Ohms and œ 100 pF
  • Frequency Range (small signal): DC to 20 kHz (- 3 dB)
  • Phase Shift below 1 kHz, <2 degrees
  • Temperature Coefficient: ñ0.1% of reading / ñC
  • Power Supply: 9 V Alkaline
ElectricalCharacteristics
CurrentRanges
ÿ30 A and 300 A ACRMS or ñ45 A and 450 A DC
ACRMSor DC
ÿñ45 A and 450 A
InrushCurrent
ÿ600A ACRMS MAX
OutputSensitivity
ÿ10 mV/A (30 A)
ÿ1 mV/A (300 A)
Accuracy(at +25øC)
(30A range) ÿñ1% of reading ñ50 mA
(300A range) ÿñ1% of reading ñ300 mA
Bandwidthto meet accuracy specification
ÿ1 kHz
PhaseShift below 1 kHz
ÿ<2 degrees
Resolution
ÿñ50 mA (30 A)
ÿñ100 mA (300 A)
LoadImpedance
ÿ> 10 k Ohms and ó100 pF
ConductorPosition Sensitivity
ÿñ1.5% relative to centre reading
FrequencyRange
(small signal) ÿDC to 20 kHz (- 3 dB)
TemperatureCoefficient
ÿñ0.1% of reading / øC
PowerSupply
ÿ9 V Alkaline, MN1604/PP3
BatteryLife
ÿ30 Hours, low battery indicator
WorkingVoltage (see Safety Standards section)
ÿ300 V ACRMS or DC

ÿ

GeneralCharacteristics
MaximumConductor Size
ÿ19 mm diameter
OutputConnection
ÿSafety BNC connector
ÿSupplied with safety 4mm adaptor
OutputZero
ÿManual adjust via thumbwheel
CableLength
ÿ2 metres
OperatingTemperature Range
ÿ-10 to +50 øC
StorageTemperature Range (with battery removed)
ÿ-20 to +85 øC
OperatingHumidity
ÿ15% to 85% (non-condensing)
Weight
ÿ250 g

ÿ

SafetyStandards
BS EN61010-1
ÿ2001
BS EN61010-2-032
ÿ2002
BS EN61010-031
ÿ2002
300 VRMS,Category III, Pollution Degree 2
ÿ
Note
ÿUse of the probe on un-insulated conductors is limited to 300 V ACRMS or DC and frequencies below 1 kHz.
EMCStandards
BS EN 61236 ÿ1998 +A1, A2, & A3