Features and benefits ofthe Fluke 113
- VCHEK LoZ low impedance measurementfunction to simultaneously test for voltage or continuity
- True-rms for accurate ac measurementson non-linear loads
- A large backlit display allows foreasy visibility in low-lit areas
- Record signal fluctuations using theMin/Max function
- Diode test for testing general-purposegermanium, silicon, and power diodes
- Integral holster with probe holdersfor easy storage
- Auto and Manual ranging for added userfunctionality
- Meets Measurement Category CAT III 600V and Category IV 300 V standards for a higher level of safety
- The optional TPAK magnetic hangerallows the user hands-free flexibility
|
| Specifications |
| VCHECK 1,2 |
| Range |
6.000 V |
|
60.00 V |
|
600.0 V |
| Resolution |
0.001 V |
|
0.01 V |
|
0.1 V |
| Accuracy |
DC, 45 to 500 Hz:2.0 % + 3 |
|
500 Hz to 1 kHz: 4.0 % + 3 |
|
| Diode test3 |
| Range |
2.000 V |
| Resolution |
0.001 V |
| Accuracy |
2.0 % + 3 |
|
| Continuity3 |
| Range |
|
| Resolution |
|
| Accuracy |
Beeper on 250 ?; detects opens or shorts of 500 ?s or longer |
|
| ?3 |
| Range |
600.0 ? |
|
6.000 k? |
|
60.00 k? |
| Resolution |
0.1 ? |
|
0.001 k? |
|
0.01 k? |
| Accuracy |
0.9 % + 2 |
|
0.9 % + 1 |
|
0.9 % + 1 |
|
| Capacitance3 |
| Range |
1000 nF |
|
10.00 ?F |
|
100.0 ?F |
|
9999 ?F |
| Resolution |
1 nF |
|
0.01 ?F |
|
0.1 ?F |
|
1 ?F |
| Accuracy |
1.9 % + 2 |
|
1.9 % + 2 |
|
1.9 % + 2 |
|
100 ?F – 1000 ?F: 1.9 % + 2 |
|
> 1000 ?F: 5 % + 20 |
|
Notes:
1 All VChek voltage ranges are specified from 60 counts to 100 % ofrange. Because inputs below 60 counts are not specified, it is possible andnormal for this and other true-rms meters to display non-zero readings when thetest leads are disconnected from a circuit or are shorted together.
2 Crest factor of ? 3 at 4000 counts, decreasing linearly to1.5 at full scale.
3 After measuring voltage, a wait time of 1 minute is required tomaintain accuracy of ohms, capacitance, diode test, and continuity.
| Specifications |
| Maximumvoltage between any terminal and earth ground |
|
| Display |
|
3 3/4-digits, 6000 counts, updates 4/sec |
|
| Operatingtemperature |
|
-10 °C to 50 °C (14 °F to 122 °F) |
|
| Storagetemperature |
|
-40 °C to 60 °C (-22 °F to 140 °F) |
|
| Temperaturecoefficient |
|
0.1 x (specified accuracy)/°C ( 28 °C) |
|
| Operatingaltitude |
|
| Storagealtitude |
|
| Relativehumidity |
|
95 % to 30 °C |
|
75 % to 40 °C |
|
45 % to 50 °C |
|
| Batterytype |
|
9 Volt Alkaline, ANSI 1604A / IEC 6F22 |
|
| Batterylife |
|
Alkaline: 300 hours typical, without backlight |
|
| Shock |
|
1 Meter drop per IEC 61010-1-2001 |
|
| Vibration |
|
Per MIL-PRF-28800 for Class 2 instrument |
|
| Size (HxWxL) |
|
167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) |
|
| Weight |
|
| Safety |
|
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 |
|
| EMIregulations |
|
Complies with FCC Part 15, Class B |
|
| Specifications |
| VCHECK |
| Input Impedance (Nominal) |
~3 k? <300 pF |
|
| VCHECK |
| Common Mode Rejection Ratio (1 k? Unbalanced) |
> 60 dB at dc, 50 or 60 Hz |
|
| ? |
| Open Circuit Test Voltage |
<2.7 V dc |
| Full Scale Voltage |
<0.7 V dc |
|
| Diode test |
| Open Circuit Test Voltage |
<2.7 V dc |
| Full Scale Voltage |
2.000 V dc |
|
| ? |
| Short Circuit Current |
<350 ?A |
|
| Diode test |
| Short Circuit Current |
<1.0 mA |
|