Home » Shop » Multimeters » True-rms Electronics Logging Multimeter with TrendCapture

True-rms Electronics Logging Multimeter with TrendCapture

Original price was: $503.99.Current price is: $318.36.

Sale!

81 in stock

SKU: FLUKE-287 Category:

Specifications(PDF)

Fluke287 True-rmsElectronics Logging Multimeter with TrendCapture

All modelsinclude:

  • Manual
  • 6 AA Batteries, installed
  • TL71 Silicone Test Leads
  • Probe Holder
  • Two AC72 Alligator Clips

SupplementalMaterial:

  • Registration Card
  • Cal Practices Document
  • CD-ROM Users’ Manual (16languages)
  • Getting Started Manual
  • Statement of CalibrationPractices Document


ÿ

  • Fast, accurate viewing of measurements withlarge ¬ VGA dot matrix display
  • TrendCapture graphing capability allowslogged data to be viewed on the meter, without being downloaded
  • Save multiple logging sessions
  • More memory-extended on-board loggingcapability including multiple sessions
  • 0.025 % basic dc accuracy
  • 100 kHz ac bandwidth
  • info button image On board help screen formeasurement functions

    The Fluke 287True-rms Electronics Logging Multimeter with TrendCapture quicklydocuments design performance and graphically displays what happened.Its? unique logging and graphing capabilities mean you no longer need todownload logged readings to a PC to detect a trend. The Fluke 287 packsmore accuracy and convenience into a handheld multimeter than ever before,putting more problem solving power in your hands. It is the ultimatehandheld tool for demanding applications that require high-precision.

    Be sure to alsocheck out the Fluke 289 True-rms Industrial Logging Multimeter withTrendCapture designed for industrial professionals.

Key Features Include:

  • New with V 1.1 Upgrade! Zoom ontrend provide unprecedented ability to view analyze TrendCapturedata; see detail at X5 magnification.
  • New with V 1.1 Upgrade! SimplifiedRecord screen when setting up recording
  • New with V 1.1 Upgrade! Loggingfunction with expanded memory for unattended monitoring of signalsover time. Using on-board TrendCapture users can graphicallyreview logged readings without needing a PC. Store up to 15,000recorded events.
  • Large 50,000 count, ¬ VGA displaywith white backlight. Multiple sets of measurement information cansimultaneously be displayed at the same time.
  • Logging function with TrendCaptureis an essential tool for documenting the performance of yourdesigns, processes or systems, or unattended monitoring while youwork on other projects. It plots measurements as a single line tohelp detect signal anomalies over time. Using on-boardTrendCapture, you can graphically view logged readings without aPC. (Software and interface cable optional).
  • Log multiple sessions or log datacontinuously for over 200 hours.
  • i-info button. On board help screensfor measurement functions. Unsure about a function? Go to thatfunction and Press the ?i? button.
  • Now, name your saved measurementsand also recall measurements made in the field
  • Real Time Clock ? for automatictime stamping of saved readings
  • Field upgradeable and expandablemeter lets you stay current as new capabilities are added
  • Multi-lingual interface
  • Min/Max/Average with Time Stamp torecord signal fluctuations
  • Soft keys, scroll buttons and easynavigation control access to secondary functions.
  • 0.025% Basic DC accuracy
  • 100 kHz ac bandwidth
  • True-rms ac voltage and current foraccurate measurements on complex signals or non-linear loads.
  • Measure up to 10A (20 A for 30seconds; 10A continuous)
  • 100 mF capacitance range
  • Temperature function
  • Relative mode to remove test leadresistance from low ohms or capacitance measurements
  • Peak capture to record transients asfast as 250 μs
  • Premium test leads and alligatorclips included
  • Optional FlukeView forms enables youto document, store and analyze individual readings or a series ofmeasurements, then convert them into professional-lookingdocuments
  • Optional magnetic hanger allows youto hang the meter for easy viewing while freeing your hands tofocus on the job.
  • Limited lifetime warranty
  • CAT III 1000 V / CAT IV 600 V safetyrated

ÿ

Specifications
Voltage DC
Accuracy ÿ0.025 %
Range andResolution ÿ50.000 mV,500.00 mV,5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage AC
Accuracy ÿ0.4 %(true-rms)
Range andResolution ÿ50.000 mV,500.00 mV,5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DC
Accuracy ÿ0.06 %
Range andResolution ÿ500.00 æA, 5000.0 æA,50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current AC
Accuracy ÿ0.6%(true-rms)
Range andResolution ÿ500.00 æA, 5000.0 æA,50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature (excluding probe)
Accuracy ÿ1.0 %
Range andResolution ÿ-200.0 øC to 1350.0 øC(-328.0 øF to 2462.0 øF)
Resistance
Accuracy ÿ0.05 %
Range andResolution ÿ500.00 Ω, 5.0000kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ,50.00 MΩ, 500.0 MΩ
Capacitance
Accuracy ÿ1.0 %
Range andResolution ÿ1.000 nF,10.00 nF 100.0 nF,1.000 æF, 10.00 æF, 100.0 æF, 1000 æF, 10.00 mF, 100.00 mF
Frequency
Accuracy ÿ0.005% + 5
Range andResolution ÿ99.999 Hz, 999.99 Hz,9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/features
Multipleon-screen displays ÿYes
True-rmsAC bandwidth ÿ100 kHz
DBV/dBm ÿYes
Conductance ÿ50.00nS
Continuitybeeper ÿYes
Battery/Fuseaccess ÿBattery / Fuse
Peak ÿ250 μS
Elapsetime clock ÿYes
Time ofday clock ÿYes
Min-Max-Avg ÿYes
DutyCycle ÿ0.01 % to 99.99 %
PulseWidth ÿ0.025 ms, 0.25 ms, 2.5 ms,1250.0 ms
Hold ÿYes
IsolatedOptical Interface ÿYes
Auto/TouchHold ÿYes
Readingmemory ÿYes
Log to PC ÿYes
Interval/EventLogging ÿYes
LoggingMemory ÿUp to 10,000 readings

ÿ

Environmental Specifications
Operating Temperature
ÿ-20 øC to +55 øC
Storage Temperature
ÿ-40 øC to +60 øC
Relative Humidity
ÿ0% to 90% (0 øC – 37 øC)
ÿ0% to 65% (37 øC – 45 øC),
ÿ0 to 45 % (45 øC – 55 øC
Electromagnetic Compatability
ÿEMC EN6 1326-1
Vibration
ÿRandom vibration perMIL-PRF-28800f Class 2
Shock
ÿ1 meter drop per IEC/EN61010-1 2nd edition

ÿ

Safety Specifications
Overvoltage category
ÿCAT III 1000 V / CAT IV600 V safety rated
Agency Approvals
ÿCSA, UL, TšV, CE

ÿ

Mechanical & General Specifications
Maximum voltage between any terminal and earth ground
ÿ1000V
Size
ÿ(HxWxL 22.2 cm x 10.2 cm x6 cm (8.75 in x 4.03 in x 2.38 in)
Weight
ÿ870.9 g (28 oz)
Battery Life
ÿ100 minimum, 200 hours inlogging mode
Battery type
ÿ6 AA alkaline batteries,NEDA 15A IEC LR6